LOW TEMPERATURE MODE •
In Low Temperature (Sentinel) mode, system starts your engine automatically when temperature falls
below a preset level.
Engine will run for programmed runtime, after which system will wait 2V2 hours and then start engine again
if temperature is still below preset level.
To activate/deactivate Low Temperature mode, press and ^ buttons simultaneously.
When mode is activated:
Parking lights will flash 4 times, then, if temperature is below preset level, engine will start.
If temperature is above preset level, system waits until it goes below preset level before starting.
For the engine to be able to start, a valid safety sequence has to be detected by the system (see "Safety
Sequence” on page 3).
If system cannot execute command (for example, safety sequence is not valid, hood is open, etc),
confirmation will be different (lights: 3).
When mode is deactivated:
Parking lights will flash twice to confirm that mode is deactivated. Applying brakes also deactivates Low
Temperature mode.
Setting the start temperature #iT
To change preset temperature at which you want your Remote Starter to start engine, press ^ and
buttons simultaneously (lights: 1 -4).
Parking lights will flash from 1 to 4 times to indicate selected start
temperature (see table opposite).
If you send command when ignition has been turned on (by
Remote Starter or key), preset start temperature does not
change. However, confirmation is still sent to indicate last
selection.
Setting the runtime Omr 3
Press buttons and d simultaneously (parking lights: 1and
Parking lights flash one to four times to indicate selected runtime
(see table opposite).
If you send this command while the ignition circuits are activated
(by remote or key), runtime does not change but confirmation is
sent to indicate last selection.
If Low Temperature (Sentinel) mode is already activated when
this command is sent, the command sets or indicates Low
Temperature mode runtime.
Note: Runtime is doubled for a diesel engine.
Number of
Flashes
Preset start
temperature
1 -5°C (23°F)
2 -15°C (5°F)
3 -20°C (-7°F)
4 -30°C (-22°F)
4).
Number of Runtime
flashes
1 2 minutes
1
2 4 minutes
3 8 minutes
4 18 minutes
^ A runtime of 2 minutes (4 min. for a diesei engine ) is not reoommended for most vehioies uniess you intend to drive off immediateiy after the
/IstroStart